40 RCBO Electronic: Power Protection for 40 Circuits

Introducing the General Protection Circuit Breaker, designed to provide comprehensive protection against a range of electrical hazards. This product offers protection against overload and short-circuit currents, as well as safeguarding against the effects of sinusoidal alternating earth fault currents. In addition, it provides protection against indirect contacts and offers additional protection against direct contacts, ensuring the safety of individuals and property. The circuit breaker also prevents fire hazards caused by insulation faults, making it an essential component for residential buildings. Classified as a Type B (3-In or Type C (5-10) In, this product is suitable for various applications. Trust in our company's reputation for producing reliable and high-quality electrical protection solutions. Ensure the safety and security of your electrical systems with the General Protection Circuit Breaker

    Release1

    Type Test current Tripping time Expected result
    B,C 1.13In t≤1h(In≤63A) Not tripping
    1.13In t≤2h(In>63A)
    B,C 1.45In t<1h(In≤63A) Tripping
    1.45In t<2h(In>63A)
    B,C 2.55In 1s<t<60s(In≤32A) Tripping
    2.55In 1s<t<120s(In>32A)

    Release2

    Type Test current Tripping time Expected result
    B 3In t≤0.1s Not tripping
    C 5In t≤0.1s
    B 5In t<0.1s Tripping
    C 10In t<0.1s

    Curve

    40 RCBO Electromagneticgav

    Specifications

    Type Standard IEC/EN 61009-1
    Electrical features Poles P 1P+N
    Type(wave form of the earth leakage sensed) AC
    Thermal-magnetic release characteristic B,C,D
    Rated current In A 6,10,16,20,25,32,40
    Rated voltage Ue V 230
    Rated sensitivity I△n A 0.03,0.05,0.1
    Rated residual making and breaking capacity I△m A 500(In≤40A)630(In>40A)
    Rated short-circuit capacity lcn A 6000
    Break timeunder I△n s ≤0.1
    Rated frequency Hz 50/60
    Rated impulse withstand voltage(1.2/50)Uimp V 4000
    Dielectric test voltage at ind.Freq.for 1min kV 2
    Insulation voltage Ui V 500
    Pollution degree 2
    Mechanical features Electrical life t 4000
    Mechanical life t 10000
    Contact position indicator Yes
    Protection degree IP20
    Ambient temperature(with daily average≤35℃) -5~+40
    Storage temperature -25~+70
    Installation Terminal connection type Cable/Pin-type busbar
    Terminal size top/bottom for cable mm2 16
    AWG 18-5
    Terminal size top/bottom for busbar mm2 10
    AWG 18-5
    Tightening torque N*m 2
    In-Ibs 18
    Mounting On DIN rail EN60715(35mm)by means of fast clip device
    Connection From top