Leave Your Message

63 MCB Circuit Breaker - High Quality Protection

Introducing our state-of-the-art circuit breaker, designed to provide unparalleled protection in both residential and non-residential buildings, as well as in the energy source industry and infrastructure. Our circuit breaker features overload protection and short circuit protection, ensuring the safety of your electrical systems. With advanced controlling capabilities, our circuit breaker offers precise management of electrical currents. It is equipped with different types of instantaneous release, including type B, type C, and type D, with varying levels of protection. Our product is reliable and efficient, offering peace of mind for your electrical projects. Trust in our company name for top-quality circuit breakers that prioritize safety and performance
    63 RCCB Electromagnetict4c

    General

    1. Overload protection
    2. Short circuit protection
    3. Controlling
    4. Used in residential building, non-residential building, energy source industry and infrastructure.
    5. According to the type of instantaneous release classified as follows: type B(3-5)ln, type C(5-10)ln, type D(10-20)ln

    Release

    Type Test current Tripping time Expected result Type Test current Tripping time Expected result
    B,C,D 1.13In t≤1h(In≤63A) Not tripping B 3In t≤0.1s Not tripping
    1.13In t≤2h(In>63A) C 5In t≤0.1s
    B,C,D 1.45In t<1h(In≤63A) Tripping D 10In t≤0.1s
    1.45In t<2h(In>63A) B 5In t<0.1s Tripping
    B,C,D 2.55In 1s<t<60s(In≤32A) Tripping C 10In t<0.1s
    2.55In 1s<t<120s(In>32A) D 20In t<0.1s
    63 MCB (2)ygb

    Specifications

    Type Standard lEC/EN 60898-1
    Electrical features Rated current ln A 1, 2, 3, 4, 5, 6, 10, 16, 20, 25, 32, 40, 50, 63
    Poles P 1, 2, 3, 4
    Rated voltage Ue V 230/400
    Insulation voltage Ui V 500
    Rated frequency Hz 50/60
    Rated breaking capacity A 4500
    Rated impulse withstand voltage(1.2/50)Uimp V 4000
    Dielectric test voltage at ind. Freq. for 1min kV 2
    Pollution degree 2
    Mechanical features Thermo-magnetic release characteristic B, C, D
    Electrical life t 6000
    Mechanical life t 20000
    Protection degree IP20
    Reference temperature for setting of thermal element 30
    Ambient temperature -5~+40
    (with daily average≤35℃)
    Storage temperature -25~+70
    Installation Terminal connection type Cable/Pin-type busbar
    Terminal size top / bottom for cable mm² 25
    AWG 3月18日
    Terminal size top / bottom for busbar mm² 25
    AWG 3月18日
    Tightening torque N*m 2
    In-Ibs 18
    Mounting On DIN rail EN 60715(35mm)by means of fast clip device
    Connection From top and bottom
    63 MCB (3)h0c